The following procedure outlines setting up and using Windows Hyper-terminal to communicate with a Brother CNC Tapping Center. The procedure was written for machines with the Brother A-00 control like the TC-S2A or TC-32A. Window Hyper-terminal can be used as a communication program with brother machines as well as a machine with a Fanuc control. The nice thing about it is that it is available on most any PC with a Windows operating system (although I have not seen it on Windows 7). It can be found under Programs/Accessories/ Communications/ Hyperterminal. So even if you don’t have Procomm or other software, you can still get programs in and out using Hyperterminal.

 

 

Brother CNC (A-00 Control) to PC: RS-232 Communication Settings and Procedure

Set the following parameters at the Brother machine control:

1. DATA BANK

2. USER PARAMETER

3. COMMUNICATION

1. SELECT PORT = 0

2. CONNECTION OBJECT =0

3. COMP COM PROTOCOL =0

4. BAUD RATE =5

5. PARITY= 2

6. STOP BIT =0

7. CHARACTER =0

8. RESPONSE MONITORING TIME =60

9. COMMUNICATION TYPE =0

10. DC1 CODE =17

11. DC2 CODE =18

12. DC3 CODE =147

13. DC4 CODE =20

14. DR SIGNAL CHECK= 0

15. ENDING DC3 CODE= 0

16. INVALID DATA= 0

17. TRANS DATA CODE= 0

18. END OF BLOCK =0

19. TV CHECK= 0

20. HEADING OUTPUT= 0

21. RESET IN SLAVE COM= 0

22. RECOVERY TIME OF RESET =0

23. DATA OVERWRITE =1

24. REMOTE OPERATION =0

25. CHECKSUM =0

26. EIA CHARACTER CODE (#) =173

27. EIA CHARACTER CODE (*) =186

28. EIA CHARACTER CODE (=) =194

29. EIA CHARACTER CODE (]) =161

30. EIA CHARACTER CODE (]) =162

To prepare Windows Hyper-Terminal:

At the PC:

Click “START”

Click “PROGRAMS”

Click ACCESSORIES”

Click “COMMUNICATION”

Click “HYPERTERMINAL”

Under “Connection Description”

Name (enter “Brother Communication” for example)

Click OK

Under “Connect To or Phone Number”

“Connect using : COM1″ (or select appropriate)

Click OK

Under “Com Properties”

Select “Port Settings”

Click on “Settings” tab

Bits per second =9600

data bits= 7

Parity =None

Stop bits =1

Flow control =XON/XOFF

Click OK

Hyper-terminal window

Click on “Properties” icon

Click on “Settings” tab

Emulation- select ANSI

Click ASCII setup button

Check all boxes EXCEPT “Append line feeds to incoming line ends”

Click OK

Click OK for Properties window

To send a program from the PC to Brother CNC using Hyper-terminal:

At the PC:

Click Transfer”

Click Send Text File from the drop-down menu

Browse to find the program to send

Click only once on the program file you want to send. Do not click “Open” yet

At the Brother CNC:

EDIT mode

Program Edit Menu

Select “External Program I/O”

Select “Input from PTR”

Type the 4-digit program number

Press “E.STA” button

Back at the PC:

Click “Open” on the selected program file

To send a program from the Brother CNC to PC using Windows Hyper-terminal:

At the PC:

Click “Transfer”

Click “Capture Text”

Type the path name and the file to receive- use a “.TXT” extension

At the Brother CNC:

EDIT mode

“Program Edit” Menu

Select “External Program I/O”

Select “OUTPUT TO PTR”

Select “Program”

Enter the program number to send

Click “Start” on the PC

Press “E.STA” button

After the file has transferred, click “Transfer”, “Capture Text”, and then “Stop”.

End

Check out www.pinpointcnc.com for machine repair information, procedures and other products

Go to www.cncalarm.com for machine alarms and details

Go to www.toyookivalve.blogspot.com for information on Toyooki products

Go to Fanuc Control Central for all Fanuc related posts

back to the top 

back to home

Filed Under Brother CNC, Communications | Leave a Comment

Tagged With , , , , , , ,

Comments

Comments are closed.